BTLJY - I 125 ISOJEX REFERENCE STANDARD
- MSDS: BTLJY
- Manufacturer: MALLINCKRODT DIAGNOSTICS
- Product Name: I 125 ISOJEX REFERENCE STANDARD
- National Stock Number: 6550-00N030336
Product Identification
Product ID:I 125 ISOJEX REFERENCE STANDARD
MSDS Date:01/01/1993
FSC:6550
NIIN:00N030336
MSDS Number: BTLJY
Responsible Party
MARYLAND HEIGHTS, MO 63043-3421
US
Emergency Phone: 314-344-3800
Info Phone: 314-344-3800
Cage: 2A916
Contractor
Telephone: 314-344-3800
Cage: 2A916
Ingredients
RADIOACTIVE IODINE
CAS: 9048-46-8
SODIUM HYDROXIDE
CAS: 1310-73-2
RTECS: WB4900000
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
SODIUM SULFITE
CAS: 7757-83-7
RTECS: WE2150000
Hazards
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-NOT EXPECTED TO BE A HEALTH
HAZARD VIA INHALATION. INGESTION-MAY CAUSE ASYMPTOMATIC
PHYSIOLOGICAL UPTAKE BY THYROID GLAND OR TISSUES. SKIN CONTACT-NOT
EXPECTED TO PRODUCE ANY ACUTE ADVERSE HEALTH EFFECTS. EYE
CONTACT-NO ADVERSE EFFECTS EXPECTED, BUT MAY CAUSE MECHANICAL
IRRITATION.
Explanation of Carcinogenicity:EXPOSURE TO SUFFICIENT QUANTITIES OF
IONIZING RADIATION CAN POTENTIALLY CAUSE BIOLOGICAL EFFECTS
(CANCER, LEUKEMIA, ETC)
Effects of Overexposure:THE HEALTH RISKS ASSOCIATED WITH CHRONIC
RADIATION EXPOSURE (CANCER, LEUKEMIA, GENETIC AND TERATOGENIC
EFFECTS) ARE BELIEVED TO INVOLVE LEVELS OF RADIATION EXPOSURE WHICH
ARE MUCH HIGHER THAN THOSE PE RMITTED OCCUPATIONALLY.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.
First Aid
First Aid:INHALATION-NOT EXPECTED TO REQUIRE FIRST AID MEASURES.
INGESTION-NOTIFY RADIATION PERSONNEL IMMEDIATELY. SKIN-IF SKIN
CONTACT OCCURS, WASH THE AFFECTED AREA THOROUGHLY WITH SOAP & WATER
UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED. ALWAYS BLOT DRY. DO
NOT ABRADE SKIN. EYE-IF SPLASH OCCURS, WASH EYE WITH WATER FOR AT
LEAST 15 MIN OR UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED. NOTIFY
RADIATION PERSON.
Fire Fighting
Extinguishing Media:USE ANY MEAN SUITABLE FOR EXTINGUISHING SURROUNDING
FIRE.
Fire Fighting Procedures:IN THE EVENT OF A FIRE, WEAR FULL PROTECTIVE
CLOTHING & NIOSH-APPROVED SELF-CONTAINED BREATHING APPARATUS WITH
FULL FACEPIECE OPERATED IN PRESSURE DEMAND MODE.
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE AN EXPLOSION HAZARD.
Accidental Release
Spill Release Procedures:IF THE PRODUCT IS RECIEVED IN A LEAKING
CONDITION OR ANY LOSS OR RELEASE OF THE RADIOACTIVE CONTENTS
OCCURS, NOTIFY YOUR RADIATION SAFETY DEPARTMENT & MALLINCKRODT AT
(314) 344-3800. ALL CLEANUP OPERA TIONS SHOULD BE DONE ACCORDING TO
THE SOP'S.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE AT 15C TO 30C. HANDLING TIME
SHOULD BE KEPT TO A MINIMUM & APPROPIATE SHIELDING SHOULD BE USED.
USE HANDLING DEVICES SUCH AS SHIELDS & TONGS.
Other Precautions:STORAGE AND DISPOSAL OF PRODUCT SHOULD BE CONTROLLED
IN A MANNER WHICH IS IN COMPLIANCE WITH THE APPROPIATE REGULATIONS
OF THE FEDERAL OR STATE GOVERNMENT AGENCY AUTHORIZED TO LICENSE THE
USE OF THIS RADIONUCLIDE.
Exposure Controls
Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE.
Ventilation:PROPERLY SEALED CONTAINERS ARE NOT EXPECTED TO REQUIRE ANY
SPECIAL VENTILATION.
Protective Gloves:DISPOSABLE PLASTIC, LATEX, OR RUBBER.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:LABCOAT.
Work Hygienic Practices:NO SMOKING, EATING OR DRINKING SHOULD BE
ALLOWED IN ANY AREA WHERE RADIOACTIVE MATERIALS ARE HANDLED OR
STORED.
Supplemental Safety and Health
CAUTION! RADIOACTIVE MATERIAL. RADIOACTIVE DRUGS MUST BE HANDLED BY
QUALIFIED PERSONNEL IN CONFORMITY WITH REGULATIONS APPROPIATE TO
THE GOVERNMENT AGENCY AUTHORIZED TO LICENSE THE USE OF THIS RADIONU
CLIDE. THE VIAL CONTAINING THE DRUG SHOULD BE KEPT WITHIN ITS
CONTAINER OR WITHIN HEAVIER SHIELDING.
Chemical Properties
HCC:A2
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Solubility in Water:SOLUBLE IN WATER
Appearance and Odor:CLEAR, COLORLESS LIQUID IN A 4 ML GLASS SCREW-CAP
VIAL.
Stability
Stability Indicator/Materials to Avoid:YES
NO INFORMATION FOUND.
Stability Condition to Avoid:STABLE UNDER ORDINARY CONDITIONS OF USE
AND STORAGE.
Hazardous Decomposition Products:MAY EMIT RADIOACTIVE FUMES CONTAINING
I-125 WHEN HEATED TO DECOMPOSITION.
Disposal
Waste Disposal Methods:ENSURE COMPLIANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.